Failure Code 


E0

 IDU & ODU Communication failure

The IDU & ODU wiring connection correct?

IDU/ODU PCB broken

 E1 

IDU Room Temperature sensor failure. IDU RT failure)

IDU sensor and PCB. 

E2

 IDU Coil temperature sensor failure.(IDU IPT failure)

IDU sensor and PCB. 

E3 

ODU Coil temperature sensor failure. (OPT)

ODU coil sensor and ODU PCB

 E4 

AC Cooling system abnormal

Gas leakage? 2-way or 3-way valve blocked etc. 

E5

 IDU/ODU mismatched failure (specially performance test on the production line)

 E6

 IDU PG Fan motor / DC fan motor works abnormal(IDU failure)

Fan motor, fan blade and PCB. 

E7

 ODU Ambient Temperature sensor failure

ODU ambient sensor and ODU PCB. 

E8 

ODU Discharge Temperature sensor failure.

ODU discharge sensor and ODU PCB. 

E9 

IPM / Compressor driving control abnormal.

ODU PCB , compressor, etc. EA ODU Current Test circuit failure

ODU PCB broken? 

Eb 

The Communication abnormal of Main PCB and Display board (IDU failure)

Display board and main PCB. 

EE 

ODU EEPROM failure.

ODU PCB broken?

Try to re-power on AC unit. 

EF 

ODU DC fan motor failure.

Fan motor, ODU PCB. 

EU 

ODU Voltage test circuit abnormal.

ODU PCB.

 P0

 IPM module protection.

ODU PCB

 P1 Over / under voltage protection.

ODU PCB broken?

Power supply abnormal? 

P2 

Over current protection.

ODU PCB broken?

Power supply abnormal? 

P4 

ODU Discharge pipe Over temperature protection.

Please check the troubleshooting for detail. 

P5 

Sub-cooling protection on Cooling mode.

Please check the troubleshooting for detail. 

P6 

Overheating protection on Cooling mode.

Please check the troubleshooting for detail. 

P7 

Overheating protection on Heating mode.

Please check the troubleshooting for detail.

 P8 

Outdoor Over temperature/Under temperature protection.

Please check the troubleshooting for detail.

P9 

Compressor driving protection (Load abnormal).

Please check the troubleshooting for detail. 

PA 

Communication failure for TOP flow unit/ Preset mode conflict. (IDU failure)

Please check the troubleshooting for detail. 

F0 

Infrared Customer feeling test sensor failure. (IDU failure)

Querying by press remote controller 

F1 

Electric Power test module failure. (IDU failure)

Querying by press remote controller 

F2 

Discharge temperature sensor failure PROTECTION.

Please check the troubleshooting for detail. 

F3 

ODU coil temperature failure PROTECTION..

Please check the troubleshooting for detail.

F4 

Cooling system gas flow abnormal PROTECTION..

Please check the troubleshooting for detail. 

F5 

PFC PROTECTION

Please check the troubleshooting for detail. 

F6 

The Compressor lack of phase / Anti-phase PROTECTION.

Please check the troubleshooting for detail. 

F7

 IPM Module temperature PROTECTION

Please check the troubleshooting for detail. 

F8 

4-Way Value reversing abnormal..

Please check the troubleshooting for detail. 

F9 

The module temperature test circuit failure.

ODU PCB 

FA 

The compressor Phase-current test circuit failure.

ODU PCB

Fb 

Limiting/Reducing frequency for Over load protection on Cooling/Heating mode.

Querying by press remote controller 

FC

 Limiting/Reducing frequency for High power consumption protection.

Querying by press remote controller 

FE 

Limiting/Reducing frequency for Module current protection ( phase current of compressor).

Querying by press remote controller 

FF 

Limiting/Reducing frequency for Module temperature protection.

Querying by press remote controller 

FH

Limiting/Reducing frequency for Compressor driving protection.

Querying by press remote controller 

FP

Limiting/Reducing frequency for anti-condensation protection..

Querying by press remote controller 

FU

Limiting/Reducing frequency for anti-frost protection.

Querying by press remote controller 

Fj 

Limiting/Reducing frequency for Discharge over temperature protection.

Querying by press remote controller 

Fn 

Limiting/Reducing frequency for ODU AC Current protection.

Querying by press remote controller 

Fy

Gas leakage protection

Please check the troubleshooting for detail. 

bf 

TVOC sensor failure IDU failure, optional)

Querying by press remote controller 

bc

PM2.5 sensor failure IDU failure, optional)

Querying by press remote controller 

bj 

Humidity sensor failure. (IDU failure)

Querying by press remote controller


Note: Remote controller FAILURE CODE Querying function

As shown in the failure codes, some of the codes (Fb~bj) need to press remote control for inspection.

While unit on operation, press the ECO button 8 times with 8 seconds, the buzzer BIBI 2 times, you can inspect the special failure code as Fb ~Fn, bj etc.